[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
GU: Troubles with restart vibrational calc.
Dear netters,
I meet some troubles when using the Intrinsic vibrational
frequencies calculation in GAMESS, by the "DECOMP"
option in $FORCE.
I have compared 2 jobs , with (for hessian calculation)
the same molecule, same geometry , same coord. unit:
JOB1: RUNTYPE=OPTIMIZE in $CONTRL
HSSEND=.TRUE. in $STATPT
NVIB=2 METHOD=NUMERIC in $FORCE
DECOMP=.TRUE. in $FORCE
JOB2: RUNTYPE=HESSIAN in $CONTRL
RDHESS=.TRUE. DECOMP=.TRUE. in $FORCE
$HESS (taken from JOB1.dat )
The two corresponding INTRINSIC VIBRATIONAL ANALYSIS
are DIFFERENT !
While the two corresponding set of (CLASSICAL)
VIBRATIONAL FREQUENCIES are identical
for example:
SETS OF VIB. FREQ
JOB1: 64, 92, 152, 214, 229 ... 3322, 3322, 3337, 3337
JOB2: 64, 92, 152, 214, 229, ... 3322, 3322, 3337, 3337
SETS OF INTRINSIC VIB. FREQ
STR. O1-O2 O3-O1 C1-O1 C1-H5 C1-H6½
JOB1: 1059.8 1097.2 1024.9 3295.7 3315.6
JOB2: 1009.8 494.9 858.7 1397.5 2367.6
I checked several things:
- the force constant matrix used in JOB2
was the last one punched after JOB1 optimization in JOB1.dat
- the cartesian force constant matrix in JOB2 is well read
(JOB1 cartesian hessian=JOB2 cartesian hessian)
- the geometry is the same in each case, with
the same orientation
- the geometry corresponds to the hessian I used
- the coordinate unity in each case
But, I have observed that JOB1 hessian matrix in INTERNAL
COORDINATES was different from which one computed in JOB2 !
, while internal coordinates are well calculated and have the same
value in each case...
Now, INTRINSIC VIBRATIONAL CALCULATION need this
matrix and this could explain my problem...
I tried to change COORD=ZMAT in COORD=CART
and create a $ZMAT group, but no amelioration was
found.
I tried another molecule (a smaller one: CH3O2) ... and
the two intrinsic vibrational analysis agree for JOB1 and JOB2.
Then, my questions are:
- do I forget something in the GAMESS cards ?
- do you know similar problems on other systems with
intrinsic vibrational analysis ?
- does intrinsic vib. analysis need something else that
the internal coordinates hessian matrix in order to work ?
-do you have any other idea to solve this problem ..?
Thank you in advance .
F. Bohr
**************************************************
* Dr F. Bohr *
* Laboratoire de Chimie Physique *
* Universite de Reims, Faculte des Sciences *
* Moulin de la Housse *
* B.P. 1039 *
* 51687 Reims Cedex 2 *
* FRANCE *
* Tel: (33) 26-05-32-33 *
* Fax: (33) 26-05-31-47 *
* E-mail: jean.brion@univ-reims.fr *
**************************************************